ASME Section V; Nondestructive Examination

Note: This Synopsis does not address numerous editorial revisions of a minor nature made by the publisher that do not affect technical requirements.

Paragraph ASME Record No. Description of Changes
Article 1, T-110(a) & T120(e) 20-2437 Revised T-110(a) (Scope) to delete the incomplete listing of NDE methods addressed in Section V. Added text to T-120(e) to indicate: “This written practice shall address the methods and techniques that are applicable to the organization’s operations and…”
Article 1, T-120(e) & Mandatory Appendices III & IV 21-2047 Revised to reference SNT-TC-1A-2020, and deleted Mandatory Appendix III and IV. This is a significant revision
Article 1, T-120(h) 21-581 Adopted ANDE-1-2020 to update ANDE-1-2015.
Article 1, T-120(j) 21-433 Revised to clarify personnel certifications made to a previous Edition of Section V remain valid until their renewal
Article 1, T-150(a) & (b) 20-2600 Revised to require procedure demonstration performance on a specimen having a known discontinuity unless otherwise stated by the referencing Code. This is a significant revision
Article 1, T-150(d)(3) 21-647 Revised “effectively reveal” to “reveal.’
Article 1, Mandatory Appendix I, I-121.2 20-352 Added definitions for “Dual Linear Array Search Unit” and “Linear Array Search Unit”
Article 1, Mandatory Appendix I, I-121.4 20-2043 Revised the definition of “Multidirectional Magnetization”
Article 1, Mandatory Appendix I, I-121.6 22-931 Deleted “magnifying aids” from the definition of “Direct Visual Examination”.
Article 1, Mandatory Appendix I, I-121.7 20-69

Revised the definition of “Hood Test”, listing distinctions specific to the Hood test.
Article 1, Mandatory Appendix I, I-121.9 18-346 Added a definition for “Sizing Accuracy”
Article 1, Mandatory Appendix II, Table II-121 21-367 Revised General Notes (a), (c) and (d) clarifying requirements for additional training and experience requirements for individuals previously certified in another radiography technique.
Article 1, Mandatory Appendix II, II-122.1 21-2387 Reduce the number of CR and DR practical examinations for Level I & II personnel with the required additional CR/DR training from 5 each to a minimum of 2 each, and revise the requirements of each test specimen. For Level I & II personnel without the required additional CR/DR training the additional 8 practical examinations shall be raw, unfiltered digital images.
Article 2, T-223 22-1375 Corrected paragraph references to “VIII-288” and “IX-288” to read “VIII-282” and “IX-282” respectively.
Article2, T-223 and Mandatory Appendix I, I-223 22-2157 Revised Paragraphs T-223 and I-223 to clarify the use of the lead letter “B” on radiographic film cartridges.
Article 2, Table T-276 20-2725 Added a General Note that the specified IQI hole and/or wire designation may not produce the required minimum sensitivity.
Article 2, Mandatory Appendix VIII, VIII-221.1(i) 21-1012 Revised to add a comma between laser and resolution (laser, resolution) by errata.
Article 2, T-277.1 & Mandatory Appendix IX, IX-277.1 21-366 Revised to clarify that the wire-type IQI placement is not required to span the full width of the weld if the sensitivity and density requirements are satisfied.
Article 4, Various 19-2943, 19-2944 1. Revised “time of flight”, when used as an adjective, to “time- of-flight”, and revised “time- of-flight”, when used as a noun, to “time of flight”. 2. Revised “backwall” to “back wall” or, when used as an adjective, to “back-wall”, and revised “back-wall” to “back wall” when used as a noun.
Article 4, T-434.1.7 21-638 Added statements requiring compliance for Non-piping Technique 1 and Technique 2 calibration blocks.
Article 4, T-451 17-2035 Added a definition for High Alloy Steel
Article 1, T-110(a) & T120(e) 20-2437 Revised T-110(a) (Scope) to delete the incomplete listing of NDE methods addressed in Section V. Added text to T-120(e) to indicate: “This written practice shall address the methods and techniques that are applicable to the organization’s operations and…”
Article 1, T-120(e) & Mandatory Appendices III & IV 21-2047 Revised to reference SNT-TC-1A-2020, and deleted Mandatory Appendix III and IV. This is a significant revision
Article 1, T-120(h) 21-581 Adopted ANDE-1-2020 to update ANDE-1-2015.
Article 1, T-120(j) 21-433 Revised to clarify personnel certifications made to a previous Edition of Section V remain valid until their renewal
Article 1, T-150(a) & (b) 20-2600 Revised to require procedure demonstration performance on a specimen having a known discontinuity unless otherwise stated by the referencing Code. This is a significant revision
Article 1, T-150(d)(3) 21-647 Revised “effectively reveal” to “reveal.’
Article 1, Mandatory Appendix I, I-121.2 20-352 Added definitions for “Dual Linear Array Search Unit” and “Linear Array Search Unit”
Article 1, Mandatory Appendix I, I-121.4 20-2043 Revised the definition of “Multidirectional Magnetization”
Article 1, Mandatory Appendix I, I-121.6 22-931 Deleted “magnifying aids” from the definition of “Direct Visual Examination”.
Article 1, Mandatory Appendix I, I-121.7 20-69

Revised the definition of “Hood Test”, listing distinctions specific to the Hood test.
Article 1, Mandatory Appendix I, I-121.9 18-346 Added a definition for “Sizing Accuracy”
Article 1, Mandatory Appendix II, Table II-121 21-367 Revised General Notes (a), (c) and (d) clarifying requirements for additional training and experience requirements for individuals previously certified in another radiography technique.
Article 1, Mandatory Appendix II, II-122.1 21-2387 Reduce the number of CR and DR practical examinations for Level I & II personnel with the required additional CR/DR training from 5 each to a minimum of 2 each, and revise the requirements of each test specimen. For Level I & II personnel without the required additional CR/DR training the additional 8 practical examinations shall be raw, unfiltered digital images.
Article 2, T-223 22-1375 Corrected paragraph references to “VIII-288” and “IX-288” to read “VIII-282” and “IX-282” respectively.
Article2, T-223 and Mandatory Appendix I, I-223 22-2157 Revised Paragraphs T-223 and I-223 to clarify the use of the lead letter “B” on radiographic film cartridges.
Article 2, Table T-276 20-2725 Added a General Note that the specified IQI hole and/or wire designation may not produce the required minimum sensitivity.
Article 2, Mandatory Appendix VIII, VIII-221.1(i) 21-1012 Revised to add a comma between laser and resolution (laser, resolution) by errata.
Article 2, T-277.1 & Mandatory Appendix IX, IX-277.1 21-366 Revised to clarify that the wire-type IQI placement is not required to span the full width of the weld if the sensitivity and density requirements are satisfied.
Article 4, Various 19-2943, 19-2944 1. Revised “time of flight”, when used as an adjective, to “time- of-flight”, and revised “time- of-flight”, when used as a noun, to “time of flight”. 2. Revised “backwall” to “back wall” or, when used as an adjective, to “back-wall”, and revised “back-wall” to “back wall” when used as a noun.
Article 4, T-434.1.7 21-638 Added statements requiring compliance for Non-piping Technique 1 and Technique 2 calibration blocks.
Article 4, T-451 17-2035 Added a definition for High Alloy Steel
Article 4, Mandatory Appendix II, Table II-440 22-440 Revised values in the Table for “Indication Limits % Full Screen” to reflect those found in the 2013 and prior Editions because the values that were changed in the 2015 Edition were incorrect. This is a significant revision.
Article 4, Mandatory Appendix III, III-479.1 21-2455, 22-442 Revised to clarify that using a manual or mechanized UT technique other than TOFD for initial flaw detection is required, due to the possible inability of detecting flaws in the lateral wave and back-wall TOFD “dead zones”. Revised the term “mechanized” to “semi-automated or automated”.
Article 4, Mandatory Appendix I & XI Nonmandatory Appendix F 22-1712 Replaced all instances of the word “paths” with the word “mode” for consistency.
Article 4, Mandatory Appendix VII, VII-421.2 20-1379 Revised to provide guidance for procedure qualification in accordance with Article 4 Mandatory Appendix VII when required by a referencing Code or Standard.
Article 4, Mandatory Appendix XI, XI-435 & XI-462.8.1 22-441 Corrected the reference to “ASTM E 2491” to read “SE-2491”.
Article 4, Mandatory Appendix XI, XI-481.1.2 21-892 Remove the 1% rule due to redundancy with the amplitude fidelity rule in XI-461.1, and updated the paragraph reference.
Article 4, Nonmandatory Appendix J, Figure J-431 22-2224 Revised Note (2) to read: “For each increase in weld thickness of 2 in. (50 mm) or fraction thereof over 14 in. (350 mm), the hole diameter shall increase 1/16 in. (1.5 mm).”
Article 4, Nonmandatory Appendix P 14-2317 Revised the title of Figure P-452.2-2 from “Top Diffraction” to “Tip Diffraction”.
Article 4, Nonmandatory Appendix S 17-1862 Added Nonmandatory Appendix S to address Ultrasonic Examination of Brazed Joints. This is a significant revision.
Article 6, Table T-672 20-2730 Add HAZs to the first row of Table T-672
Article 6, T-676.4 19-2863 Revised to include “Glasses and Lenses” consistent with T-777.2.
Article 6, T-692(c) 21-370 Removed “number or letter designation”.
Article 7, T-765 20-786 Revised for consistency with SE-709.
Article 7, T-777.2 21-369 Revised for consistency with T-676.4.
Article 8, Mandatory Appendix XI 19-1983 Added new Mandatory Appendix XI, describing tangential field examination for detection and measurement of surface breaking cracks.Tiss is a significant revision.
Article 9, T-921.3 20-1233 Revised to allow the use of “characters” in addition to lines and other visible artifacts for procedure demonstration
Article 9, T-953 18-2052 Amended Remote Visual to accommodate deployment mechanisms like UAS/UAV & robots, allowing an exception for Direct Visual Equivalence.
Article 10, Mandatory Appendix XI, XI-1063.6 21-1003 Reversed the sequence of RB and RC in the equation for final system correction factor (FSCF)
Article 12, Mandatory Appendix III 20-779, 20-780 Added a mandatory appendix describing the methodology to determine the sensitivity of the instrumentation used in an Acoustic Emission test, according to the location methodology used, zonal or planar. This is a significant revision.
Article 12, Nonmandatory Appendix A Substantially improved graphic images from those shown in the prior Edition.
Article 22, SE-999 20-2651 Adopted ASTM E 999-20 to update SE 999
Article 22, SE-1030 21-2334 Adopted ASTM E1030-2021 to update SE-1030
Article 22, SE-1114 21-1073 Adopted ASTM E1114-2020 to update SE-1114
Article 22, SE-1165 21-1071 Adopted E1165-2020 to update SE-1165
Article 22, SE-2597 22-889 Deleted SE-2597
Article 23, SE-213 22-891 Adopted ASTM E213-2022 to update SE-213
Article 23, SE-273 Adopted ASTM E273-2020 to updated SA-273
Article 23, SE-745 20-2679 Adopted ASTM A745 – 2020 to update SA-745
Article 23, SE-797 21-2333 Adopted ASTM E797-2021 to update SE-797
Article 23, SE-2491 20-2680 Adopted ASTM E2491 – 2018 as SE-2491.
Article 23, SE-2700 20-2681 Adopted ASTM E2700 – 2020 to update SE-2700
Article 23, SD-7091 21-1072 Adopted ASTM D7091-2021 to update SD-7091
Article 25, SD-1186 22-1474 Deleted SD-1186.
Article 26, SE-243 20-2652 Adopted ASTM E243 – 2018 to update SE-243.
Article 29, SE-750 21-2328 Adopted ASTM E750-2020 to update SE-750
Article 29, SE-976 22-888 Adopted ASTM E976-15(2021) to update SA-976
Article 29, SE-1067 20-793 Adopt ASTM E1067-18 to update SE-1067
Article 29, SE-1118 20-2862 Adopted ASTM E1118–2020 to update SE-1118
Article 29, SE-1419 20-2863 Deleted ASTM E1419 – 2015.
Article 29, SE-2075 20-2864 Adopted ASTM E2075–2020 to update SE-2075
Article 31, SE-2261 22-890 Adopted ASTM E2261-17(2021) to update of SE-2261.